Hydrophobic & Oleophobic Coatings
Consulte os modelos ECLEAR, a construção do material, as aplicações, a janela de processo e os requisitos de validação desta família técnica.

O que compõe a estrutura do material.
As camadas são apresentadas na ordem funcional; a construção exata depende do grau.
- 01Qualified substrate or hardcoat
- 02Optional activation/primer interface
- 03Thin hydrophobic or oleophobic topcoat
Lower surface energy for water beading and easier cleaning.
01A hydrophobic topcoat changes the interaction between the exposed surface and water. Instead of spreading, a droplet forms a higher contact angle and can roll away more readily when gravity, airflow or wiping force is applied.
02Oleophobic and easy-clean performance are related but not identical to water repellency. Oils, fingerprints and cleaning agents have different surface tensions, so each target should be measured with an appropriate liquid, method and durability sequence.
03The topcoat is thin and interface-sensitive. Contamination, incomplete activation, excessive coating mass or incompatibility with a hardcoat, PVD film or ink can reduce adhesion or create optical non-uniformity.
Desempenho definido em torno da aplicação.
Os benefícios são avaliados no substrato, no processo e no conjunto final pretendidos.
Water beading and roll-off
Reduced adhesion of fingerprints, smudges and grime
Easier cleaning on qualified surfaces
Integration support for hardcoat and metallized stacks
Da definição do material a uma estrutura de produção qualificada.
A qualificação conecta o material, a conversão e a linha de produção do cliente.
Identify hardcoat, metalized surface, polymer or glass and its cleaning history.
Control surface energy, activation and time before coating.
Stabilize coating mass, uniformity and the approved cure route.
Measure water, oil and easy-clean behavior after relevant wear and chemicals.
Evidências a reunir antes da liberação da especificação.
Use substratos, condições de processo e sequências de envelhecimento representativos.
- Static or dynamic water-contact angle using a defined droplet volume
- Roll-off or sliding-angle test on the intended part orientation
- Fingerprint, oil and cleaning evaluation with controlled materials
- Abrasion and chemical durability of retained easy-clean performance
- Optical appearance and intercoat adhesion on the finished stack
Os valores exigem método e revisão aprovada.
Valores típicos orientam a seleção; os limites controlados vêm da TDS aprovada.
Valores típicos não são especificações. Os limites finais dependem da TDS ECLEAR aprovada e da validação do cliente.
Perguntas dos engenheiros antes do teste em linha.
Defina a função, as interfaces e a janela de processo antes da amostragem.
Is contact angle alone enough to select an easy-clean coating?+
No. Contact angle is useful, but roll-off, hysteresis, oil interaction, abrasion durability and compatibility with the underlying stack are also important.
Can the coating be used on both polymer and glass?+
The public platform includes qualified hardcoated or metallized PC and acrylic surfaces, with other polymers and glass evaluated project by project.
Can ECLEAR recommend a grade from an application description alone?+
A first shortlist is possible, but a production recommendation requires the substrate, layer construction, equipment, process sequence, test method and acceptance criteria. ECLEAR normally moves from requirement definition to laboratory matching, samples, line trial and a frozen approved specification.
Are the values shown on this page guaranteed specifications?+
No. Website values and constructions are selection guidance. Guaranteed limits, test conditions, packaging and shelf life are controlled only by the latest ECLEAR-approved TDS, quality agreement and customer qualification record.
Onde esta plataforma é avaliada.
Cada aplicação ainda exige compatibilidade da estrutura completa e validação na linha.
Parâmetros a controlar.
Registre a janela completa do processo, não apenas um ajuste nominal.
- Validate cleanliness and surface energy immediately before application.
- Control coating mass, uniformity and cure according to the approved grade.
- Measure initial and aged easy-clean performance after the relevant abrasion and chemical cycles.
- Confirm compatibility with adjacent anti-fog, AR, PVD and ink layers.
O que precisamos saber.
Essas informações permitem à ECLEAR restringir o grau e o plano de validação.
- Q1What is the exposed surface chemistry?
- Q2Is the priority water repellency, oil repellency, easy cleaning or all three?
- Q3Which cleaners and abrasion cycles represent real use?
- Q4What optical and appearance limits apply?
O que um teste disciplinado deve revelar cedo.
As verificações antecipadas reduzem o risco de escala e evitam comparações incorretas.
Poor adhesion on a contaminated or low-energy surface
Loss of performance after an unrepresentative abrasion test
Optical non-uniformity from excessive coating mass
Incompatibility with PVD, ink or another functional layer
Documentos técnicos controlados.
Solicite a revisão atual para o grau ECLEAR e a aplicação selecionados.
As construções típicas e os conceitos de aplicação são fornecidos apenas para a seleção do material. Disponibilidade, estrutura, desempenho e condições de processo dependem do grau e estão sujeitos à TDS ECLEAR vigente, aos testes de aplicação e à qualificação final do cliente.
Sistemas de materiais relacionados.
Revise os materiais adjacentes que interagem com este produto na mesma estrutura ou processo.
Valide a estrutura completa, não um material isolado.
Compartilhe o substrato, a construção, o processo e os critérios de aceitação para uma recomendação objetiva.