ECLEAR Anti-Fog Coating Systems
Consulte os modelos ECLEAR, a construção do material, as aplicações, a janela de processo e os requisitos de validação desta família técnica.

O que compõe a estrutura do material.
As camadas são apresentadas na ordem funcional; a construção exata depende do grau.
- 01FC route: prepared unprimed PC / thermally cured anti-fog layer
- 02FT route: PC / qualified hardcoat / plasma activation / hydrophilic anti-fog topcoat
- 03Application-specific edge, ink and masking zones
Hydrophilic control of condensation at the optical surface.
01Fog reduces visibility when condensed water forms many discrete droplets that scatter light. A hydrophilic anti-fog surface encourages the moisture to spread into a more continuous film, reducing droplet-driven scattering.
02Anti-fog is not one universal formulation. FC-100 is positioned for qualified unprimed polycarbonate, while FT-100 uses a different route for a plasma-activated hardcoated PC surface. Mixing the preparation routes can cause immediate or aged adhesion failure.
03Initial clarity is only the first screen. Cleaning, abrasion, skin oils, packaging contact, humidity cycling and time between plasma treatment and coating can determine whether anti-fog performance survives real use.
Desempenho definido em torno da aplicação.
Os benefícios são avaliados no substrato, no processo e no conjunto final pretendidos.
Hydrophilic fog-management mechanism
Routes for both qualified unprimed PC and hardcoated PC
Designed for safety eyewear, shields and visor applications
Application support covering pretreatment, coating and cure
Da definição do material a uma estrutura de produção qualificada.
A qualificação conecta o material, a conversão e a linha de produção do cliente.
Determine whether the PC is bare, primed, hardcoated, printed or metallized.
Use the approved FC or FT preparation and activation sequence.
Control wet film, drainage, edge zones, flash-off and thermal cure.
Run the agreed fog, cleaning, abrasion and conditioning sequence.
Evidências a reunir antes da liberação da especificação.
Use substratos, condições de processo e sequências de envelhecimento representativos.
- Defined hot-fog, cold-to-warm or customer-specific condensation test
- Optical transmission and haze before, during and after conditioning
- Adhesion to bare or activated hardcoated PC
- Cleaning-agent, sweat, abrasion and packaging-contact durability
- Appearance uniformity around edges, holes, masks and printed zones
Os valores exigem método e revisão aprovada.
Valores típicos orientam a seleção; os limites controlados vêm da TDS aprovada.
Valores típicos não são especificações. Os limites finais dependem da TDS ECLEAR aprovada e da validação do cliente.
Perguntas dos engenheiros antes do teste em linha.
Defina a função, as interfaces e a janela de processo antes da amostragem.
Does an anti-fog coating repel water?+
Normally no. Hydrophilic anti-fog technology spreads condensed water; hydrophobic technology promotes beading and roll-off. They solve different moisture problems and must not be described as interchangeable.
Can FT-100 be coated directly on any hardcoat?+
No. The hardcoat chemistry, plasma energy, surface cleanliness and treatment-to-coating time must be validated as a system.
Can ECLEAR recommend a grade from an application description alone?+
A first shortlist is possible, but a production recommendation requires the substrate, layer construction, equipment, process sequence, test method and acceptance criteria. ECLEAR normally moves from requirement definition to laboratory matching, samples, line trial and a frozen approved specification.
Are the values shown on this page guaranteed specifications?+
No. Website values and constructions are selection guidance. Guaranteed limits, test conditions, packaging and shelf life are controlled only by the latest ECLEAR-approved TDS, quality agreement and customer qualification record.
Onde esta plataforma é avaliada.
Cada aplicação ainda exige compatibilidade da estrutura completa e validação na linha.
Parâmetros a controlar.
Registre a janela completa do processo, não apenas um ajuste nominal.
- Do not substitute the FC and FT preparation routes.
- For FT-100, validate hardcoat chemistry, plasma energy, treatment-to-coating time and surface cleanliness.
- Control wet-film uniformity, flash-off, cure and handling after cure.
- Use the customer-agreed fog test, conditioning and abrasion sequence.
O que precisamos saber.
Essas informações permitem à ECLEAR restringir o grau e o plano de validação.
- Q1Is the PC surface uncoated, primed, hardcoated, printed or metallized?
- Q2Is plasma treatment available and how is it controlled?
- Q3Which anti-fog standard and durability sequence must be met?
- Q4Will the coated surface contact cleaners, skin oils or packaging materials?
O que um teste disciplinado deve revelar cedo.
As verificações antecipadas reduzem o risco de escala e evitam comparações incorretas.
Coating a hardcoat without the required activation step
Using an unspecified cleaner that changes hydrophilic performance
Blocking, print transfer or contamination during packaging
Treating one anti-fog grade description as a universal specification
Documentos técnicos controlados.
Solicite a revisão atual para o grau ECLEAR e a aplicação selecionados.
As construções típicas e os conceitos de aplicação são fornecidos apenas para a seleção do material. Disponibilidade, estrutura, desempenho e condições de processo dependem do grau e estão sujeitos à TDS ECLEAR vigente, aos testes de aplicação e à qualificação final do cliente.
Sistemas de materiais relacionados.
Revise os materiais adjacentes que interagem com este produto na mesma estrutura ou processo.
Valide a estrutura completa, não um material isolado.
Compartilhe o substrato, a construção, o processo e os critérios de aceitação para uma recomendação objetiva.