Rivestimenti fotocromatici ECLEAR per lenti e visiere
WPC-501 e la serie PCR-501 creano una tinta fotocromatica reversibile su substrati ottici qualificati, con controllo di colore, attivazione e recupero.

Che cosa contiene la struttura del materiale.
Gli strati sono mostrati in ordine funzionale; la struttura esatta dipende dal grado.
- 01Qualified lens substrate
- 02Compatible hardcoat or adhesion interface
- 03WPC-501 or qualified PCR-501-series photochromic functional layer
- 04Optional protective topcoat after compatibility validation
Gradi identificati per la selezione tecnica.
Ogni modello ECLEAR indica un ruolo e una struttura distinti. Le corrispondenze di produzione restano controllate nell’anagrafica prodotti ECLEAR per la tracciabilità.
Reversible optical absorption controlled by light and temperature.
01Photochromic molecules reversibly change optical state under an activating spectrum. The coated lens darkens while activation continues and returns toward its clear state after the source is removed.
02Darkening and fading are kinetic processes, so temperature, spectral power, irradiance, exposure time and coating thickness must be controlled whenever two samples are compared. A result obtained under one lamp cannot be transferred directly to another test condition.
03The photochromic layer is part of a stack. Its color, adhesion and lifetime depend on the substrate, hardcoat interface, cure and any protective topcoat. ECLEAR validates the complete construction rather than the photochromic sol in isolation.
Prestazioni definite in funzione dell’applicazione.
I vantaggi vengono valutati sul substrato, sul processo e sull’assieme finale previsti.
Reversible tint response under activating light
Compatible coating-route options for lens production
Designed for integration with qualified ECLEAR hardcoat systems
Application engineering for color, response and durability targets
Dalla definizione del materiale a una struttura produttiva qualificata.
La qualifica collega materiale, trasformazione e linea produttiva del cliente.
Set clear-state, activated-state, color and recovery targets with a test protocol.
Select substrate, hardcoat interface, photochromic layer and optional topcoat.
Stabilize bath, dip or spin profile, film thickness and cure.
Measure complete response curves before and after weathering and use simulation.
Evidenze da raccogliere prima del rilascio della specifica.
Utilizzare substrati, condizioni di processo e sequenze di invecchiamento rappresentativi.
- Clear and activated luminous transmittance at a defined temperature
- Darkening and fading curves using a specified source and irradiance
- Color coordinates and uniformity on the final lens geometry
- Intercoat adhesion, abrasion, humidity and accelerated weathering
- Batch-to-batch comparison against an approved golden sample
I valori richiedono un metodo e una revisione approvata.
I valori tipici guidano la selezione; i limiti controllati provengono dalla TDS approvata.
I valori tipici non sono specifiche. I limiti finali dipendono dalla TDS ECLEAR approvata e dalla validazione del cliente.
Domande degli ingegneri prima di una prova in linea.
Definire ruolo, interfacce e finestra di processo prima del campionamento.
Why can two laboratories report different activation speeds?+
The result changes with sample temperature, source spectrum, intensity, distance, exposure history and the definition of the endpoint. ECLEAR requires the complete method with every reported value.
Can WPC-501 be applied by both dip and spin coating?+
The public platform supports dip- and spin-coating routes, subject to the approved grade, viscosity, part geometry and production process.
Can ECLEAR recommend a grade from an application description alone?+
A first shortlist is possible, but a production recommendation requires the substrate, layer construction, equipment, process sequence, test method and acceptance criteria. ECLEAR normally moves from requirement definition to laboratory matching, samples, line trial and a frozen approved specification.
Are the values shown on this page guaranteed specifications?+
No. Website values and constructions are selection guidance. Guaranteed limits, test conditions, packaging and shelf life are controlled only by the latest ECLEAR-approved TDS, quality agreement and customer qualification record.
Dove viene valutata questa piattaforma.
Ogni applicazione richiede comunque compatibilità dell’intera struttura e validazione in linea.
Parametri da controllare.
Registrare l’intera finestra di processo, non un solo valore nominale.
- Control substrate cleanliness, bath condition, withdrawal/spin profile and cure.
- Measure response at defined temperature, activation source, dose and time.
- Evaluate clear-state transmission, activated transmission and recovery as a complete curve.
- Approve the final hardcoat/photochromic/topcoat stack on production parts.
Che cosa dobbiamo sapere.
Questi dati consentono a ECLEAR di restringere il grado e il piano di validazione.
- Q1What substrate and base hardcoat are currently used?
- Q2What activated color and transmission range are required?
- Q3How are darkening and fading measured by the customer?
- Q4What weathering, humidity and abrasion exposure is required?
Che cosa deve rivelare subito una prova rigorosa.
I controlli precoci riducono il rischio di scala e i confronti errati tra materiali.
Comparing response rates measured at different temperatures or UV intensities
Color drift caused by thickness or cure variation
Intercoat adhesion failure in an unvalidated layer stack
Assuming one response target applies to every substrate and geometry
Documenti tecnici controllati.
Richiedere la revisione corrente per il grado ECLEAR e l’applicazione selezionati.
Le strutture tipiche e i concetti applicativi sono forniti esclusivamente per la selezione del materiale. Disponibilità, struttura, prestazioni e condizioni di processo dipendono dal grado e sono soggette alla TDS ECLEAR approvata più recente, alle prove applicative e alla qualifica finale del cliente.
Sistemi di materiali correlati.
Esaminare i materiali adiacenti che interagiscono con questo prodotto nella stessa struttura o nello stesso processo.
Convalidare l’intera struttura, non un singolo materiale.
Condividere substrato, struttura, processo e criteri di accettazione per una raccomandazione mirata.