Hydrofobowe i oleofobowe powłoki easy-clean
Powłoki wierzchnie ECLEAR obniżają energię powierzchniową, wspierają perlenie wody i ułatwiają czyszczenie kwalifikowanych powierzchni optycznych.

Elementy konstrukcji warstwowej materiału.
Warstwy pokazano w kolejności funkcjonalnej; dokładna konstrukcja zależy od wariantu.
- 01Qualified substrate or hardcoat
- 02Optional activation/primer interface
- 03Thin hydrophobic or oleophobic topcoat
Lower surface energy for water beading and easier cleaning.
01A hydrophobic topcoat changes the interaction between the exposed surface and water. Instead of spreading, a droplet forms a higher contact angle and can roll away more readily when gravity, airflow or wiping force is applied.
02Oleophobic and easy-clean performance are related but not identical to water repellency. Oils, fingerprints and cleaning agents have different surface tensions, so each target should be measured with an appropriate liquid, method and durability sequence.
03The topcoat is thin and interface-sensitive. Contamination, incomplete activation, excessive coating mass or incompatibility with a hardcoat, PVD film or ink can reduce adhesion or create optical non-uniformity.
Wydajność oceniana w kontekście zastosowania.
Korzyści ocenia się na docelowym podłożu, w procesie i w gotowym zespole.
Water beading and roll-off
Reduced adhesion of fingerprints, smudges and grime
Easier cleaning on qualified surfaces
Integration support for hardcoat and metallized stacks
Od definicji materiału do zakwalifikowanej konstrukcji produkcyjnej.
Kwalifikacja łączy materiał, sposób przetwarzania i linię produkcyjną klienta.
Identify hardcoat, metalized surface, polymer or glass and its cleaning history.
Control surface energy, activation and time before coating.
Stabilize coating mass, uniformity and the approved cure route.
Measure water, oil and easy-clean behavior after relevant wear and chemicals.
Dowody wymagane przed zatwierdzeniem specyfikacji.
Należy użyć reprezentatywnych podłoży, warunków procesu i sekwencji starzenia.
- Static or dynamic water-contact angle using a defined droplet volume
- Roll-off or sliding-angle test on the intended part orientation
- Fingerprint, oil and cleaning evaluation with controlled materials
- Abrasion and chemical durability of retained easy-clean performance
- Optical appearance and intercoat adhesion on the finished stack
Każda wartość wymaga metody i zatwierdzonej rewizji.
Wartości typowe wspierają dobór; kontrolowane limity pochodzą z zatwierdzonej TDS.
Wartości typowe nie są specyfikacją. Ostateczne limity wynikają z zatwierdzonej karty TDS ECLEAR i walidacji klienta.
Pytania inżynierów przed próbą na linii.
Przed pobraniem próbek określ rolę materiału, interfejsy i okno procesu.
Is contact angle alone enough to select an easy-clean coating?+
No. Contact angle is useful, but roll-off, hysteresis, oil interaction, abrasion durability and compatibility with the underlying stack are also important.
Can the coating be used on both polymer and glass?+
The public platform includes qualified hardcoated or metallized PC and acrylic surfaces, with other polymers and glass evaluated project by project.
Can ECLEAR recommend a grade from an application description alone?+
A first shortlist is possible, but a production recommendation requires the substrate, layer construction, equipment, process sequence, test method and acceptance criteria. ECLEAR normally moves from requirement definition to laboratory matching, samples, line trial and a frozen approved specification.
Are the values shown on this page guaranteed specifications?+
No. Website values and constructions are selection guidance. Guaranteed limits, test conditions, packaging and shelf life are controlled only by the latest ECLEAR-approved TDS, quality agreement and customer qualification record.
Obszary oceny tej platformy.
Każde zastosowanie wymaga zgodności pełnego układu warstw i walidacji linii.
Parametry wymagające kontroli.
Zapisuj pełne okno procesu, a nie tylko jedną wartość nominalną.
- Validate cleanliness and surface energy immediately before application.
- Control coating mass, uniformity and cure according to the approved grade.
- Measure initial and aged easy-clean performance after the relevant abrasion and chemical cycles.
- Confirm compatibility with adjacent anti-fog, AR, PVD and ink layers.
Informacje, których potrzebujemy.
Dane te pozwalają ECLEAR zawęzić wariant i plan walidacji.
- Q1What is the exposed surface chemistry?
- Q2Is the priority water repellency, oil repellency, easy cleaning or all three?
- Q3Which cleaners and abrasion cycles represent real use?
- Q4What optical and appearance limits apply?
Co rzetelna próba powinna ujawnić na wczesnym etapie.
Wczesne kontrole awarii zmniejszają ryzyko skalowania i błędnych porównań.
Poor adhesion on a contaminated or low-energy surface
Loss of performance after an unrepresentative abrasion test
Optical non-uniformity from excessive coating mass
Incompatibility with PVD, ink or another functional layer
Kontrolowana dokumentacja techniczna.
Poproś o aktualną rewizję dla wybranego wariantu ECLEAR i zastosowania.
Typowe konstrukcje i koncepcje zastosowań służą wyłącznie do doboru materiału. Dostępność, budowa, wydajność i warunki procesu zależą od wariantu oraz podlegają najnowszej zatwierdzonej TDS ECLEAR, testom aplikacyjnym i końcowej kwalifikacji klienta.
Powiązane systemy materiałowe.
Sprawdź sąsiednie materiały współpracujące z tym produktem w tym samym układzie lub procesie.
Waliduj cały układ, a nie pojedynczy materiał.
Przekaż podłoże, konstrukcję, proces i kryteria akceptacji, aby uzyskać trafną rekomendację.