ECLEAR Anti-Fog Coating Systems
Xem các mã ECLEAR, cấu trúc vật liệu, ứng dụng, cửa sổ quy trình và yêu cầu xác nhận của dòng kỹ thuật này.

Thành phần của cấu trúc lớp vật liệu.
Các lớp được trình bày theo thứ tự chức năng; cấu trúc chính xác phụ thuộc từng mã.
- 01FC route: prepared unprimed PC / thermally cured anti-fog layer
- 02FT route: PC / qualified hardcoat / plasma activation / hydrophilic anti-fog topcoat
- 03Application-specific edge, ink and masking zones
Hydrophilic control of condensation at the optical surface.
01Fog reduces visibility when condensed water forms many discrete droplets that scatter light. A hydrophilic anti-fog surface encourages the moisture to spread into a more continuous film, reducing droplet-driven scattering.
02Anti-fog is not one universal formulation. FC-100 is positioned for qualified unprimed polycarbonate, while FT-100 uses a different route for a plasma-activated hardcoated PC surface. Mixing the preparation routes can cause immediate or aged adhesion failure.
03Initial clarity is only the first screen. Cleaning, abrasion, skin oils, packaging contact, humidity cycling and time between plasma treatment and coating can determine whether anti-fog performance survives real use.
Hiệu năng được đánh giá theo ứng dụng.
Lợi ích được đánh giá trên nền vật liệu, quy trình và cụm lắp ráp cuối cùng dự kiến.
Hydrophilic fog-management mechanism
Routes for both qualified unprimed PC and hardcoated PC
Designed for safety eyewear, shields and visor applications
Application support covering pretreatment, coating and cure
Từ định nghĩa vật liệu đến cấu trúc sản xuất được phê duyệt.
Quá trình phê duyệt liên kết vật liệu, phương án gia công và dây chuyền của khách hàng.
Determine whether the PC is bare, primed, hardcoated, printed or metallized.
Use the approved FC or FT preparation and activation sequence.
Control wet film, drainage, edge zones, flash-off and thermal cure.
Run the agreed fog, cleaning, abrasion and conditioning sequence.
Bằng chứng cần thu thập trước khi ban hành quy cách.
Sử dụng nền vật liệu, điều kiện quy trình và chuỗi lão hóa đại diện.
- Defined hot-fog, cold-to-warm or customer-specific condensation test
- Optical transmission and haze before, during and after conditioning
- Adhesion to bare or activated hardcoated PC
- Cleaning-agent, sweat, abrasion and packaging-contact durability
- Appearance uniformity around edges, holes, masks and printed zones
Mọi giá trị đều cần phương pháp và phiên bản được phê duyệt.
Giá trị điển hình hỗ trợ lựa chọn; giới hạn kiểm soát lấy từ TDS đã phê duyệt.
Giá trị điển hình không phải là quy cách bảo đảm. Giới hạn cuối cùng tuân theo TDS ECLEAR đã duyệt và kết quả thẩm định của khách hàng.
Các câu hỏi kỹ thuật trước khi chạy thử dây chuyền.
Xác định vai trò vật liệu, bề mặt tiếp xúc và cửa sổ quy trình trước khi yêu cầu mẫu.
Does an anti-fog coating repel water?+
Normally no. Hydrophilic anti-fog technology spreads condensed water; hydrophobic technology promotes beading and roll-off. They solve different moisture problems and must not be described as interchangeable.
Can FT-100 be coated directly on any hardcoat?+
No. The hardcoat chemistry, plasma energy, surface cleanliness and treatment-to-coating time must be validated as a system.
Can ECLEAR recommend a grade from an application description alone?+
A first shortlist is possible, but a production recommendation requires the substrate, layer construction, equipment, process sequence, test method and acceptance criteria. ECLEAR normally moves from requirement definition to laboratory matching, samples, line trial and a frozen approved specification.
Are the values shown on this page guaranteed specifications?+
No. Website values and constructions are selection guidance. Guaranteed limits, test conditions, packaging and shelf life are controlled only by the latest ECLEAR-approved TDS, quality agreement and customer qualification record.
Các lĩnh vực đánh giá nền tảng này.
Mỗi ứng dụng vẫn cần kiểm tra tính tương thích của toàn bộ cấu trúc và xác nhận trên dây chuyền.
Các thông số cần kiểm soát.
Ghi lại toàn bộ cửa sổ quy trình, không chỉ một giá trị danh nghĩa.
- Do not substitute the FC and FT preparation routes.
- For FT-100, validate hardcoat chemistry, plasma energy, treatment-to-coating time and surface cleanliness.
- Control wet-film uniformity, flash-off, cure and handling after cure.
- Use the customer-agreed fog test, conditioning and abrasion sequence.
Thông tin chúng tôi cần.
Các dữ liệu này giúp ECLEAR thu hẹp mã vật liệu và kế hoạch xác nhận.
- Q1Is the PC surface uncoated, primed, hardcoated, printed or metallized?
- Q2Is plasma treatment available and how is it controlled?
- Q3Which anti-fog standard and durability sequence must be met?
- Q4Will the coated surface contact cleaners, skin oils or packaging materials?
Những rủi ro cần được phát hiện sớm trong thử nghiệm có kiểm soát.
Kiểm tra lỗi sớm giúp giảm rủi ro mở rộng sản xuất và tránh so sánh vật liệu sai lệch.
Coating a hardcoat without the required activation step
Using an unspecified cleaner that changes hydrophilic performance
Blocking, print transfer or contamination during packaging
Treating one anti-fog grade description as a universal specification
Tài liệu kỹ thuật được kiểm soát.
Yêu cầu phiên bản hiện hành cho mã ECLEAR và ứng dụng đã chọn.
Cấu trúc điển hình và khái niệm ứng dụng chỉ nhằm hỗ trợ lựa chọn vật liệu. Tình trạng cung ứng, cấu trúc, hiệu năng và điều kiện quy trình phụ thuộc từng mã và phải tuân theo TDS ECLEAR mới nhất đã được phê duyệt, thử nghiệm ứng dụng và phê duyệt cuối cùng của khách hàng.
Các hệ vật liệu liên quan.
Xem xét các vật liệu lân cận tương tác với sản phẩm này trong cùng cấu trúc hoặc quy trình.
Xác nhận toàn bộ cấu trúc, không chỉ một vật liệu riêng lẻ.
Cung cấp nền vật liệu, cấu trúc, quy trình và tiêu chí chấp nhận để nhận khuyến nghị phù hợp.