ECLEAR Anti-Fog Coating Systems
Tinjau model ECLEAR, konstruksi material, aplikasi, jendela proses, dan persyaratan validasi untuk keluarga teknis ini.

Isi struktur berlapis material.
Lapisan ditampilkan menurut urutan fungsi; konstruksi tepatnya bergantung pada grade.
- 01FC route: prepared unprimed PC / thermally cured anti-fog layer
- 02FT route: PC / qualified hardcoat / plasma activation / hydrophilic anti-fog topcoat
- 03Application-specific edge, ink and masking zones
Hydrophilic control of condensation at the optical surface.
01Fog reduces visibility when condensed water forms many discrete droplets that scatter light. A hydrophilic anti-fog surface encourages the moisture to spread into a more continuous film, reducing droplet-driven scattering.
02Anti-fog is not one universal formulation. FC-100 is positioned for qualified unprimed polycarbonate, while FT-100 uses a different route for a plasma-activated hardcoated PC surface. Mixing the preparation routes can cause immediate or aged adhesion failure.
03Initial clarity is only the first screen. Cleaning, abrasion, skin oils, packaging contact, humidity cycling and time between plasma treatment and coating can determine whether anti-fog performance survives real use.
Kinerja yang dinilai berdasarkan aplikasi.
Manfaat dievaluasi pada substrat, proses, dan rakitan akhir yang dituju.
Hydrophilic fog-management mechanism
Routes for both qualified unprimed PC and hardcoated PC
Designed for safety eyewear, shields and visor applications
Application support covering pretreatment, coating and cure
Dari definisi material hingga struktur produksi yang terkualifikasi.
Kualifikasi menghubungkan material, jalur konversi, dan lini produksi pelanggan.
Determine whether the PC is bare, primed, hardcoated, printed or metallized.
Use the approved FC or FT preparation and activation sequence.
Control wet film, drainage, edge zones, flash-off and thermal cure.
Run the agreed fog, cleaning, abrasion and conditioning sequence.
Bukti yang dikumpulkan sebelum spesifikasi dirilis.
Gunakan substrat, kondisi proses, dan urutan penuaan yang mewakili penggunaan sebenarnya.
- Defined hot-fog, cold-to-warm or customer-specific condensation test
- Optical transmission and haze before, during and after conditioning
- Adhesion to bare or activated hardcoated PC
- Cleaning-agent, sweat, abrasion and packaging-contact durability
- Appearance uniformity around edges, holes, masks and printed zones
Setiap nilai memerlukan metode dan revisi yang disetujui.
Nilai tipikal membantu pemilihan; batas terkendali berasal dari TDS yang disetujui.
Nilai tipikal bukan spesifikasi. Batas akhir tunduk pada TDS ECLEAR yang disetujui dan validasi pelanggan.
Pertanyaan teknis sebelum uji coba lini.
Tentukan peran material, antarmuka, dan jendela proses sebelum meminta sampel.
Does an anti-fog coating repel water?+
Normally no. Hydrophilic anti-fog technology spreads condensed water; hydrophobic technology promotes beading and roll-off. They solve different moisture problems and must not be described as interchangeable.
Can FT-100 be coated directly on any hardcoat?+
No. The hardcoat chemistry, plasma energy, surface cleanliness and treatment-to-coating time must be validated as a system.
Can ECLEAR recommend a grade from an application description alone?+
A first shortlist is possible, but a production recommendation requires the substrate, layer construction, equipment, process sequence, test method and acceptance criteria. ECLEAR normally moves from requirement definition to laboratory matching, samples, line trial and a frozen approved specification.
Are the values shown on this page guaranteed specifications?+
No. Website values and constructions are selection guidance. Guaranteed limits, test conditions, packaging and shelf life are controlled only by the latest ECLEAR-approved TDS, quality agreement and customer qualification record.
Bidang evaluasi platform ini.
Setiap aplikasi tetap memerlukan kompatibilitas seluruh struktur dan validasi lini.
Parameter yang harus dikendalikan.
Catat seluruh jendela proses, bukan hanya satu pengaturan nominal.
- Do not substitute the FC and FT preparation routes.
- For FT-100, validate hardcoat chemistry, plasma energy, treatment-to-coating time and surface cleanliness.
- Control wet-film uniformity, flash-off, cure and handling after cure.
- Use the customer-agreed fog test, conditioning and abrasion sequence.
Informasi yang kami perlukan.
Data ini membantu ECLEAR mempersempit grade dan rencana validasi.
- Q1Is the PC surface uncoated, primed, hardcoated, printed or metallized?
- Q2Is plasma treatment available and how is it controlled?
- Q3Which anti-fog standard and durability sequence must be met?
- Q4Will the coated surface contact cleaners, skin oils or packaging materials?
Hal yang harus terungkap lebih awal dalam uji coba yang disiplin.
Pemeriksaan kegagalan dini mengurangi risiko peningkatan skala dan perbandingan material yang keliru.
Coating a hardcoat without the required activation step
Using an unspecified cleaner that changes hydrophilic performance
Blocking, print transfer or contamination during packaging
Treating one anti-fog grade description as a universal specification
Dokumen teknis terkendali.
Minta revisi terbaru untuk grade ECLEAR dan aplikasi yang dipilih.
Konstruksi tipikal dan konsep aplikasi diberikan hanya untuk pemilihan material. Ketersediaan, struktur, kinerja, dan kondisi proses bergantung pada grade serta tunduk pada TDS ECLEAR terbaru yang disetujui, pengujian aplikasi, dan kualifikasi akhir pelanggan.
Sistem material terkait.
Tinjau material di sekitarnya yang berinteraksi dengan produk ini dalam struktur atau proses yang sama.
Validasi seluruh struktur, bukan satu material saja.
Bagikan substrat, konstruksi, proses, dan kriteria penerimaan untuk memperoleh rekomendasi yang terarah.